FEATURES
The FP series power pack is an easy to assemble compact electro-hydraulic unit. The features of versatility and modularity make it possible to obtain many hydraulic circuit combinations for various plant design requirements. This catalogue has been written to help the user choose the power pack components to be used in his/her application. However, it cannot foresee all the application combinations that can be implemented so, in some cases, it is necessary to consult our commercial engineering department.
For applications with very complex circuits, there is the possibility of assembling standard modular blocks on the power pack for Cetop valves and other special or requested blocks.
APPLICATION FIELDS
•LIFT TRUCKS
•LIFTING PLATFORMS AND TABLES
•AUTO LIFTS
•CRANES FOR SMALL TRUCKS
•SNOWPLOWS
•INDUSTRIAL SECTOR AUTOMATIONS (MACHINE TOOLS, FOOD INDUSTRY, TEXTILE INDUSTRY)
A fundamental part of the central power pack is the flange body made of die cast aluminium alloy.
The choice of components is wide and the main characteristics are as follows:
•GEAR PUMPS GROUP 05 / 1 FROM 0.25 TO 9.8 CC.
•DC POWERED MOTORS 12/24 V, SERVICE FROM 0.35 TO 3 KW
•THREE-PHASE AND SINGLE-PHASE AC MOTORS WITH POWER OUTPUT UP TO 4 KW
•WITH STANDARD OR ACCORDING TO DRAWING (WITH MINIMUM OVERALL DIMENSION)
•STEEL SHEET TANKS UP TO 25 LITRES
•PLASTIC TANKS UP TO 10 LITRES IN CAPACITY
OPERATING LIMITS
Pressione intermittente di lavoro 290 bar (secondo il tipo di pompa)
•Intermittent operating pressure 290 bar (according to the pump type)
•Maximum flow rate 20 l/min
•Maximum operating temperature
◦80°C (with steel sheet tank)
◦70°C (with polyethylene tank)
◦60°C (with polypropylene tank)
•Mineral based hydraulic fluid ISO 6743-4 (DIN 51524)
◦Minimum viscosity 12 mm2/s
◦Maximum viscosity 80 mm2/s
◦Maximum starting viscosity 500 mm2/s
•Minimum ambient temperature – 15°C
•Maximum ambient temperature 40°C (with peaks of 50°C)